These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The effects of high frequency, low intensity ultrasound therapy on parotid flow rates.
    Author: Sankar V, Prihoda T, Terezhalmy G.
    Journal: Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Nov; 106(5):e16-9. PubMed ID: 18718790.
    Abstract:
    OBJECTIVES: Saliva plays a critical role in maintaining oral health and comfort. Development of a single device capable of simulating salivary flow with no taste or adverse side effects is desirable. STUDY DESIGN: This clinical investigation on 23 healthy volunteers with no dry mouth complaints evaluated the effectiveness of ultrasonic therapy in mechanical stimulation of the parotid gland to increase saliva flow. Stimulated and unstimulated parotid saliva was collected. Differences in mean salivary flow rates and affects of age and ethnicity were measured. RESULTS: The mean difference between stimulated and unstimulated saliva flow rates was 0.009 mL/min +/- SD = 0.042, t (df = 22) = 1.27 with P = .31. There were no significant differences of age (P = .26), gender (P = .38), or race/ethnicity (P = .58) for the difference of stimulated and unstimulated conditions. CONCLUSIONS: Results indicate that high-frequency low-intensity ultrasound therapy is not effective in stimulating salivary flow rates.