These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Nafion film/K(+)-exchanged glass optical waveguide sensor for BTX detection.
    Author: Ablat H, Yimit A, Mahmut M, Itoh K.
    Journal: Anal Chem; 2008 Oct 15; 80(20):7678-83. PubMed ID: 18781774.
    Abstract:
    An optical waveguide (OWG) sensor for the detection of BTX gases is reported. The highly sensitive element of this sensor was made by coating the copper Nafion film over a single-mode potassium ion exchanged glass OWG. We used the OWG sensor to detect toluene gas as a typical example BTX gas. The sensor exhibits a linear response to toluene in the range of 0.25-4250 ppm with response and recovery times less than 25 s. The sensor has a short response time, high sensitivity, and good reversibility.