These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The influence of dynamic fatigue loading on the separate components of the bracket-cement-enamel system.
    Author: Algera TJ, Kleverlaan CJ, Prahl-Andersen B, Feilzer AJ.
    Journal: Am J Dent; 2008 Aug; 21(4):239-43. PubMed ID: 18795520.
    Abstract:
    PURPOSE: To evaluate the influence of cyclic loading and type of adhesive on the shear bond strength of the bracket-cement-enamel bond. METHODS: The materials studied were: Transbond XT (a Bis-GMA resin composite cement), Fuji Ortho LC (a resin-modified glass-ionomer cement), and Fuji IX Fast (a conventional glass-ionomer cement). The shear bond strength (SBS) and the shear bond fatigue limits (SBFL) were determined after 72-hour storage in 37 degrees C water for the cement itself, the button-cement interface, the cement-enamel interface, and the bracket-cement-enamel system. The SBFL was determined with the aid of the "staircase method" at 10,000 cycles. The results were analyzed using ANOVA and Tukey HSD post hoc test (P < 0.05). RESULTS: ANOVA showed significant differences between the SBS of the materials. Fatigue was observed in all substrate combinations, with the exception for the Fuji IX Fast cement-enamel and the Fuji Ortho LC bracket-cement-enamel combinations.
    [Abstract] [Full Text] [Related] [New Search]