  • Title: Polyaniline-carbon nanotube composite film for cholesterol biosensor.
    Author: Dhand C, Arya SK, Datta M, Malhotra BD.
    Journal: Anal Biochem; 2008 Dec 15; 383(2):194-9. PubMed ID: 18817744.
    Abstract:
    Nanocomposite film composed of polyaniline (PANI) and multiwalled carbon nanotubes (MWCNT), prepared electrophoretically onto indium tin oxide (ITO)-coated glass plate, was used for covalent immobilization of cholesterol oxidase (ChOx) via N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry. Results of linear sweep voltammetric measurements reveal that ChOx/PANI-MWCNT/ITO bioelectrode can detect cholesterol in the range of 1.29 to 12.93 mM with high sensitivity of 6800 nA mM(-1) and a fast response time of 10 s. Photometric studies for ChOx/PANI-MWCNT/ITO bioelectrode indicate that it is thermally stable up to 45 degrees C and has a shelf life of approximately 12 weeks when stored at 4 degrees C. The results of these studies have implications for the application of this interesting matrix (PANI-MWCNT) toward the development of other biosensors.