These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A comparison between the responses of neutral red and acridine orange: acridine orange should be preferential and alternative to neutral red as a dye for the monitoring of contaminants by means of biological sensors. Author: Manente S, De Pieri S, Iero A, Rigo C, Bragadin M. Journal: Anal Biochem; 2008 Dec 15; 383(2):316-9. PubMed ID: 18835233. Abstract: The acridine orange (AO) and neutral red (NR) dyes, commonly used as probes to measure the internal pH in acidic vesicles, are compared in this article. The comparison between the two dyes (arising from calculations taking into account their analytical constants) illustrated that the use of AO is preferential to that of NR because the AO response is sensitive over the whole pH range between 4.0 and 7.4, whereas the NR response is effective only between pHs 4.0 and 6.0. In addition, it became evident from the mitochondrial respiration response that NR, unlike AO, is a protonophore. When taken into consideration, these two properties suggest that AO is more suitable than NR as an indicator of toxicity measurements in water samples because the environmental toxic compounds induce pH changes in the acidic vesicles of biological structures that are used as environmental biosensors.[Abstract] [Full Text] [Related] [New Search]