Search MEDLINE/PubMed
Title: Globally optimal superconducting magnets part II: symmetric MSE coil arrangement. Author: Tieng QM, Vegh V, Brereton IM. Journal: J Magn Reson; 2009 Jan; 196(1):7-11. PubMed ID: 18848794. Abstract: A globally optimal superconducting magnet coil design procedure based on the Minimum Stored Energy (MSE) current density map is outlined. The method has the ability to arrange coils in a manner that generates a strong and homogeneous axial magnetic field over a predefined region, and ensures the stray field external to the assembly and peak magnetic field at the wires are in acceptable ranges. The outlined strategy of allocating coils within a given domain suggests that coils should be placed around the perimeter of the domain with adjacent coils possessing alternating winding directions for optimum performance. The underlying current density maps from which the coils themselves are derived are unique, and optimized to possess minimal stored energy. Therefore, the method produces magnet designs with the lowest possible overall stored energy. Optimal coil layouts are provided for unshielded and shielded short bore symmetric superconducting magnets.[Abstract] [Full Text] [Related] [New Search]