These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of pulsatile perfusion and cold storage for paired kidney allografts. Author: Shah AP, Milgrom DP, Mangus RS, Powelson JA, Goggins WC, Milgrom ML. Journal: Transplantation; 2008 Oct 15; 86(7):1006-9. PubMed ID: 18852670. Abstract: Use of pulsatile perfusion to optimize outcomes in deceased donor kidney transplantation remains controversial. This study is a retrospective analysis of all cadaveric renal allografts procured locally by our center over a 3-year period. Kidney pairs were identified in which one kidney underwent pulsatile perfusion and transplantation at our center, whereas the contra-lateral kidney underwent cold storage and transplantation at another center. Eighty-eight percent of the exported kidneys were six-antigen matches. Study outcomes included 1-year graft and patient survival, delayed graft function, and need for posttransplant dialysis. Recipients had similar demographic and disease characteristics. Survival for pulsatile perfusion and cold storage were 95% and 88% (graft, P=0.43) and 98% and 90% (patient, P=0.36), respectively. The incidence of delayed graft function was 5% and 35% (P<0.01), whereas posttransplant dialysis was 5% and 30% (P<0.01), for pulsatile perfusion and cold storage, respectively. These data support routine use of pulsatile perfusion.[Abstract] [Full Text] [Related] [New Search]