These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of Sebia Capillarys capillary electrophoresis with the Primus high-pressure liquid chromatography in the evaluation of hemoglobinopathies. Author: Keren DF, Hedstrom D, Gulbranson R, Ou CN, Bak R. Journal: Am J Clin Pathol; 2008 Nov; 130(5):824-31. PubMed ID: 18854277. Abstract: The Sebia Capillarys (capillary zone electrophoresis [CE]) and the Primus Resolution high-pressure liquid chromatography (HPLC) were used to prospectively evaluate 297 samples for hemoglobinopathies. Hemoglobin (Hb) A levels were similar on both techniques (mean, 96.2% and SD, 5.7% by CE; mean, 96.8% and SD, 5.5% by HPLC), but HbA2 levels were higher by CE (mean, 2.8%; SD, 0.8%) than by HPLC (mean, 2.3%; SD, 0.8%). HbS had higher values by CE (mean, 40.6%; SD, 18.9%) than by HPLC (mean, 38.4%; SD, 18.9%). In cases with Hg S, HbA2 levels were greater by HPLC (mean, 4.0%; SD, 1.0%) than by CE (mean, 3.1%; SD, 0.8%). HbA2 was occasionally not separated sufficiently from HbC for measurement by CE, but did separate from HbE by CE. Both methods identified HbS, HbC, HbE, HbS, and HbC together, HbA2&prime, HbD-Los Angeles, HbF variant, HbG-Philadelphia, HbS-G Philadelphia, and Hb Lepore.[Abstract] [Full Text] [Related] [New Search]