These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Reference hearing threshold levels for short duration signals.
    Author: Poulsen T, Legarth SV.
    Journal: Int J Audiol; 2008 Oct; 47(10):665-74. PubMed ID: 18923987.
    Abstract:
    Hearing thresholds for clicks and tonebursts were measured on 26 otologically normal persons (age 18-25 years) using the earphones Sennheiser HDA 200 and Telephonics TDH 39. The test signals are specified in IEC 60645-3 and in ISO 389-9. The acoustic test signals were presented both as a single stimulus and as repeated stimuli with the repetition rate of 20 Hz. The frequencies used for the toneburst were: 250, 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz. Test signals and measurement methods were all in accordance with the recommendations given in ISO 389-9: Preferred test conditions for the determination of reference hearing threshold levels. The results are given as peak-to-peak equivalent threshold sound pressure levels (peETSPL). The results are in good agreement with other sparse results from literature and are part of the basis for the ISO 389-6 standard from 2007.
    [Abstract] [Full Text] [Related] [New Search]