Title: Differential pulse anodic stripping voltammetry of lead (lI) benzoylacetonate in chloroform: Application to the analysis of free-lead gasoline and gas oil samples. Author: Pournaghi-Azar MH, Ansary-Fard AH. Journal: Talanta; 1998 Aug; 46(4):607-14. PubMed ID: 18967183. Abstract: The voltammetric characteristics of lead(II) benzoylacetonate in chloroform at the mercury electrode are investigated. The conditions for nearly reversible reduction of lead(II) were optimized. Anodic stripping voltammetry for the determination of trace-lead was developed using differential pulse technique to strip amalgamed lead from hanging mercury drop electrode. The experimental conditions, such as scanning rate of electrode potential and deposition time of lead were optimized. The calibration graph was linear over concentration range 5x10(-8)-10(-6) M of lead(II). The detection limit was 2.5x10(-9) and the relative standard deviation for the determination of 4x10(-7) M Pb(II) was 2%. Preceded by decomposition of organolead compounds with concentrated nitric acid, then ashing at 300 degrees C and a solvent extraction of Pb(II) benzoylacetonate in chloroform, the suitability of the proposed method for the determination of lead in free-lead gasoline and gas oil was demonstrated as a typical example of application.[Abstract] [Full Text] [Related] [New Search]