These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Short- and long-term stability of resonant quartz temperature sensors. Author: Spassov L, Gadjanova V, Velcheva R, Dulmet B. Journal: IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1626-31. PubMed ID: 18986952. Abstract: A new miniaturized design of the thermosensitive quartz resonator (TSQR) using an NLC cut (yxl/ -31 degrees 30') with a fundamental frequency of 29.3 MHz was created in the Acoustoelectronics Laboratory of ISSPBAS for use in a wide temperature range (4.2 K to 450 K) as highly sensitive quartz temperature sensors (QTS). This paper presents the results of the investigations of the short- and long-term frequency stability of QTS. The short-term frequency stability of QTS was measured for averaging times up to 150 s at three constant temperatures: liquid helium (4.2 K), liquid nitrogen (77 K), and melting ice (0 degrees C). The short-term frequency stability is 6.8 * 10(-9) at 0 degrees C for t = 15 s, which permits a temperature sensitivity of 2 * 10(-4) K. The long-term stability (aging) was investigated at room temperature and at 80 degrees C for 500 days. The aging characteristics at 25 degrees C and 80 degrees C are compared. It was observed that the frequency change does not exceed 5 * 10(-7) after the 25th day of accelerated aging at 80 degrees C. This guarantees a reliable operation of the sensor, without additional calibration, for several years.[Abstract] [Full Text] [Related] [New Search]