These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Suitability of saphenous vein graft lesions for the use of distal embolic protection devices. Author: Mehta SK, Stolker JM, Frutkin AD, Marso SP. Journal: J Invasive Cardiol; 2008 Nov; 20(11):568-70. PubMed ID: 18987394. Abstract: The use of distal embolic protection devices (EPD) in saphenous vein graft percutaneous interventions (SVG-PCI) has been associated with a decrease in adverse events. Currently, there are limited data regarding the percentage of SVG lesions that are suitable for EPD deployment. We retrospectively reviewed 131 SVG-PCI procedures occurring over 18 months for suitability for EPD deployment, utilizing previously published suitability criteria. We found that 49% of cases were suitable for EPD use, which is similar to results from other studies. Given the data supporting the use of EPD use in SVG-PCI, we feel that these findings should motivate interventional operators to establish benchmark standards for employing EPDs to improve the care of patients undergoing SVG-PCI.[Abstract] [Full Text] [Related] [New Search]