These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Internal fixation of proximal humerus fractures using the T2-proximal humeral nail. Author: Popescu D, Fernandez-Valencia JA, Rios M, Cuñé J, Domingo A, Prat S. Journal: Arch Orthop Trauma Surg; 2009 Sep; 129(9):1239-44. PubMed ID: 19066921. Abstract: INTRODUCTION: Surgical management of proximal humerus fractures remains controversial and there is an increasing interest in intramedullary nailing. Created to improve previous designs, the T2-proximal humeral nail (PHN) (Stryker) has been recently released, and the English literature lacks a series evaluating its results. We present a clinical prospective study evaluating this implant for proximal humeral fractures. METHOD: We evaluated the functional and radiological results and possible complications. Twenty-nine patients with displaced fractures of the proximal humerus were treated with this nail. One patient was lost right after surgery and excluded from the assessment. Eighteen patients were older than 70 years. RESULTS: There were 21 fractures of the proximal part of the humerus and 7 fractures that also involved the shaft; 15 of the fractures were two-part fractures (surgical neck), 5 were three-part fractures, and 1 was a four-part fracture. All fractures healed in a mean period of 2.7 months. There was one delayed union that healed in 4 months. One case of avascular necrosis of the humeral head was observed (a four-part fracture), but remained asymptomatic and did not require further treatment. In one case a back-out of one proximal screw was observed. A final evaluation with a minimum 1 year follow-up was performed by an independent observer; in 18 patients, the mean Constant score was 65.7 or 76.1% with the adjustment of age and gender; in 19 patients, the mean Oxford Shoulder Score was 21.7. The results obtained with the T2-PHN nail indicate that it represents a safe and reliable method in the treatment of two- and three-part fractures of the proximal humerus. The proximal fixation mechanism diminishes the rate of back-out of the screws, a frequent complication described in the literature. Better functional results were obtained from the patients younger than 70 years, but these were not statistically significant.[Abstract] [Full Text] [Related] [New Search]