These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Bias in trials comparing paired continuous tests can cause researchers to choose the wrong screening modality. Author: Glueck DH, Lamb MM, O'Donnell CI, Ringham BM, Brinton JT, Muller KE, Lewin JM, Alonzo TA, Pisano ED. Journal: BMC Med Res Methodol; 2009 Jan 20; 9():4. PubMed ID: 19154609. Abstract: BACKGROUND: To compare the diagnostic accuracy of two continuous screening tests, a common approach is to test the difference between the areas under the receiver operating characteristic (ROC) curves. After study participants are screened with both screening tests, the disease status is determined as accurately as possible, either by an invasive, sensitive and specific secondary test, or by a less invasive, but less sensitive approach. For most participants, disease status is approximated through the less sensitive approach. The invasive test must be limited to the fraction of the participants whose results on either or both screening tests exceed a threshold of suspicion, or who develop signs and symptoms of the disease after the initial screening tests. The limitations of this study design lead to a bias in the ROC curves we call paired screening trial bias. This bias reflects the synergistic effects of inappropriate reference standard bias, differential verification bias, and partial verification bias. The absence of a gold reference standard leads to inappropriate reference standard bias. When different reference standards are used to ascertain disease status, it creates differential verification bias. When only suspicious screening test scores trigger a sensitive and specific secondary test, the result is a form of partial verification bias. METHODS: For paired screening tests with bivariate normally distributed scores, we give formulae and programs to quantify the effect of paired screening trial bias on a paired comparison of area under the curves. We fix the prevalence of disease, and the chance a diseased subject manifests signs and symptoms. We derive the formulas for true sensitivity and specificity, and those for the sensitivity and specificity observed by the study investigator. RESULTS: The observed area under the ROC curves is quite different from the true area under the ROC curves. The typical direction of the bias is a strong inflation in sensitivity, paired with a concomitant slight deflation of specificity. CONCLUSION: In paired trials of screening tests, when area under the ROC curve is used as the metric, bias may lead researchers to make the wrong decision as to which screening test is better.[Abstract] [Full Text] [Related] [New Search]