These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: PMMA biosensor for nucleic acids with integrated mixer and electrochemical detection. Author: Nugen SR, Asiello PJ, Connelly JT, Baeumner AJ. Journal: Biosens Bioelectron; 2009 Apr 15; 24(8):2428-33. PubMed ID: 19168346. Abstract: This paper discusses the design, microfabrication and use of an electrochemical biosensor based on a polymer substrate for cost effectiveness and disposability. As model analyte, amplified hsp70 mRNA from Cryptosporidium parvum was chosen. Microfluidic channels were fabricated in poly(methyl methacrylate) (PMMA) using hot embossing with a copper master. The electrochemical transducer, an interdigitated ultramicroelectrode array (IDUA) was also realized directly on the PMMA surface. First, the unstructured PMMA surface was UV functionalized. An 8 min UV treatment resulted in a carboxylic acid density of approximately 8 nmol/cm(2) on the PMMA surface. The surface carboxylic acid groups were then conjugated to cystamine using water-soluble carbodiimide chemistry. Gold (200 nm) was then evaporated onto the thiol-functionalized surface. Using standard photolithography techniques, the IDUA containing 10 microm wide electrodes with 5 microm gaps was then formed followed by a gold etch. The PMMA surface containing the microchannel was subsequently bonded to the PMMA surface containing the IDUA using UV-assisted thermal bonding. The additional UV treatment also served to decrease the water contact angle of the surface from 62.5 degrees +/-0.7 degrees to 48.4 degrees +/-0.2 degrees thus, aiding with the capillary flow in the device. The hsp70 mRNA was isolated from C. parvum oocysts and amplified using nucleic acid sequence-based amplification (NASBA). The amplicon was detected in a sandwich hybridization assay with capture probe-coated superparamagnetic beads and reporter probe-tagged liposomes. The liposomes entrapped potassium ferro/ferrihexacyanide to enable amperometric quantification of the amplicon on the IDUA. Amplified mRNA from only 1 oocyst was detectable with this PMMA biosensor. The final detection device measured approximately 10 mm x 40 mm x 3 mm and contained two detection channels for dual analyses.[Abstract] [Full Text] [Related] [New Search]