These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Detection and characterization of hepatocellular carcinoma in rats with liver cirrhosis: diagnostic value of combined use of MR positive and negative contrast agents.
    Author: Guo DM, Qiu TS, Bian J, Liu SF, Wang CZ.
    Journal: Hepatobiliary Pancreat Dis Int; 2009 Feb; 8(1):65-70. PubMed ID: 19208518.
    Abstract:
    BACKGROUND: Gadolinium-enhanced multi-phase dynamic imaging has improved the accuracy of the diagnosis of hypervascular hepatocellular carcinoma (HCC), but using gadolinium-enhanced dynamic imaging alone is problematic in evaluating hypovascular HCC. This work aimed at evaluating the combined use of superparamagnetic iron oxide (SPIO)-enhanced and gadolinium set in distinguishing HCCs from regenerative nodules (RNs) in a rat model induced by diethylnitrosamine (DEN). METHODS: DEN-induced HCC model rats (n=40) and control rats (n=10) were studied. From weeks 16 to 19 after DEN administration, 4 animals were scanned every week. The hepatic changes were tested with a 1.5 Tesla magnet, and MR images of SPIO-enhanced and gadolinium set were obtained. According to the pathologic changes, the tumorigenesis was divided into HCC and RN (diameter of nodules > or =3 mm). Diagnostic accuracy of the combined SPIO-enhanced and gadolinium set and the gadolinium set alone was evaluated using receiver-operating characteristic curves. Sensitivity and specificity of the combined SPIO-enhanced and gadolinium set and the gadolinium set alone were calculated. RESULTS: The listed tests were completed in 29 rats (21 treated and 8 controls). One hundred and six nodules (82 HCCs, 24 RNs) were analyzed. The Az value and sensitivity with the combined SPIO-enhanced and gadolinium set (Az 0.94, sensitivity 0.96) were higher than those with the gadolinium set alone (Az 0.92, sensitivity 0.89). Using the combined SPIO-enhanced and gadolinium set led to detection of 6 nodules which were negative in the gadolinium set alone and 3 nodules were correctly characterized. CONCLUSION: Using the combined SPIO-enhanced and gadolinium set improved the detectability of HCCs and the SPIO-enhanced imaging compensated for the gadolinium set in differentiating HCCs from RNs in a rat model.
    [Abstract] [Full Text] [Related] [New Search]