These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Artificial pneumothorax with position adjustment for computed tomography-guided percutaneous core biopsy of mediastinum lesions. Author: Lin ZY, Li YG. Journal: Ann Thorac Surg; 2009 Mar; 87(3):920-4. PubMed ID: 19231419. Abstract: PURPOSE: This study was designed to assess the use of artificial pneumothorax with position adjustment to gain a pleural space approach in computed tomographic-guided core biopsy of mediastinal masses. DESCRIPTION: Eleven patients with mediastinal lesions who were undergoing percutaneous core biopsies received an artificial pneumothorax with a 22-gauge lumbar puncture needle. Each patient's position was adjusted to place the lesion as high as possible in the thoracic cavity. Air was injected until the lung was displaced from the path of the biopsy needle. After completion of the biopsy, a comparable volume of air was aspirated. EVALUATION: In all patients, satisfactory displacement of the lung from the biopsy site was achieved with the artificial pneuomothorax procedure enabling the target lesion to be reached. No postoperative air leaks requiring tube drainage were encountered. CONCLUSIONS: Artificial pneumothorax with position adjustment is a safe and effective method that provides access for computed tomographic-guided biopsy of mediastinal lesions without the risks of traversing aerated lung tissue and with a relatively low volume of injected air.[Abstract] [Full Text] [Related] [New Search]