Search MEDLINE/PubMed
Title: Performance of the far-IR beamline of the 6 MeV tabletop synchrotron light source. Author: Monirul Haque M, Yamada H, Moon A, Yamada M. Journal: J Synchrotron Radiat; 2009 Mar; 16(Pt 2):299-306. PubMed ID: 19240343. Abstract: The performance of the far-infrared (FIR) beamline of the 6 MeV tabletop synchrotron light source MIRRORCLE-6FIR dedicated to far-infrared spectroscopy is presented. MIRRORCLE-6FIR is equipped with a perfectly circular optical system (PhSR) placed around the 1 m-long circumference electron orbit. To illustrate the facility of this light source, the FIR output as well as its spectra were measured. The optimum optical system was designed by using the ray-tracing simulation code ZEMAX. The measured FIR intensity with the PhSR in place is about five times higher than that without the PhSR, which is in good agreement with the simulation results. The MIRRORCLE-6FIR spectral flux is compared with a standard thermal source and is found to be 1000 times greater than that from a typical thermal source at approximately 15 cm(-1). It is also observed that the MIRRORCLE-6FIR radiation has a highly coherent nature. The broadband infrared allows the facility to reach the spectral range from 10 cm(-1) to 100 cm(-1). MIRRORCLE-6FIR, owing to a large beam current, the PhSR mirror system, a large dynamic aperture and small ring energy, can deliver a bright flux of photons in the FIR/THz region useful for broadband spectroscopy.[Abstract] [Full Text] [Related] [New Search]