These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Classification of congenital ventricular defects using echocardiography for transcatheter closure]. Author: Lai YQ, Huang XS. Journal: Nan Fang Yi Ke Da Xue Xue Bao; 2009 Feb; 29(2):323-5. PubMed ID: 19246313. Abstract: OBJECTIVE: To determine the anatomical variation and classification of ventricular septal defect (VSD) using echocardiography for percutaneous catheter closure in eligible cases. METHOD: The isolated ventricular septal defect was diagnosed with echocardiography in 240 patients , and 167 patients screened by transthoracic echocardiography were suitable for percutaneous catheter closure, but only 62 with isolated perimembranous VSD voluntarily received the procedure. RESULTS: The procedure was successful in 58 patients, with a success rate of 93.5% with Amplatzer device. The diameter of VSD ranged from 2.4 to 13.9 (mean 5.3-/+2.0) mm with echocardiography, and the size of Amplatzer device ranged from 4-18 (mean 8.3-/+2.9) mm. Perimembranous ventricular septal defect was complicated by aneurysm formation in 22 patients. Residual trivial or mild shunt was seen in seven (12%) patients at 24 h and one (1.7%) patient at 3 months. Seven (12.1%) patients developed heart block, 3 (5.2%) had intermittence and transient complete heart block, and one had transient second degree atrioventricular block disappearing in 3 to 10 days, and 3 (5.2%) patients had complete right bundle branch block lasting for one month. None of the patients developed significant aortic regurgitation (P>0.05), although 22 showed a superior margin of the defect less than 3 mm from the aortic valve. The mean distance from the aortic valve was 3.7-/+2.7 (1.0 to 10.5) mm. No significant mitral and tricuspid regurgitation occurred in these patients. Four patients had unsuccessful procedures. CONCLUSIONS: Percutaneous closure with Amplatzer device can be carried out successfully in a majority of suitable defects screened using transthoracic echocardiography. Echocardiography can exactly demonstrate the anatomical variation and classification of ventricular septal defect in adults. Attention should be given to the misdiagnosis by echocardiography of a doubly committed defect as a perimembranous outflow defect. Heart block can be an important complication of the procedure.[Abstract] [Full Text] [Related] [New Search]