Search MEDLINE/PubMed
Title: Non-invasive and rapid analysis for observation of internal structure of press-coated tablet using X-ray computed tomography. Author: Tokudome Y, Ohshima H, Otsuka M. Journal: Drug Dev Ind Pharm; 2009 Jun; 35(6):678-82. PubMed ID: 19274513. Abstract: BACKGROUND: Since the internal structure of a tablet can be measured without destruction of the sample by X-ray computed tomography (CT), it could be applied to quality control of tablets during the manufacturing process. AIM: A novel, fast, noninvasive tablet observation method was developed to evaluate the internal structure of commercial press-coated tablets by using X-ray CT. METHOD: Thirty-two CT image slices of four kinds of commercial press-coated tablets (tablets A, B, C, and D) were measured 300 m interval between edges of the tablet by using an X-ray CT. The thinnest layer thickness of the tablets and distance between centers of gravity (DCG) of tables were calculated. RESULTS: The order of the TLT of the tablets was tablet B > tablet C > tablet D > tablet A. The result indicated that the order of DCG was tablet A > tablet D > tablet C > tablet B. Noninvasive observation of the internal structure of commercial, press-coated tablets by X-ray CT has been demonstrated to be useful in quality control of production. CONCLUSION: The internal structure of press-coated tablets could be observed without pretreatment, without destruction, and very rapidly by X-ray CT.[Abstract] [Full Text] [Related] [New Search]