These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Orotracheal tube ignited by an electrocautery device during tracheostomy].
    Author: Villarroya González A, Longás Valién J, Vicente Armijo JJ, Cuartero Lobera J.
    Journal: Rev Esp Anestesiol Reanim; 2009 Jan; 56(1):47-9. PubMed ID: 19284128.
    Abstract:
    Endotracheal tube fire during surgery is a rare complication associated with carbon dioxide laser surgery and, less often, with electrocautery. We report a case in which tracheostomy was performed because of recurrence of a laryngeal tumor. During the procedure the endotracheal tube ignited when the lumen was opened with the electrocautery device.