These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Increased accuracy in heparin and protamine administration decreases bleeding: a pilot study. Author: Runge M, Møller CH, Steinbrüchel DA. Journal: J Extra Corpor Technol; 2009 Mar; 41(1):10-4. PubMed ID: 19361026. Abstract: Three to 5 percent of the patients undergoing cardiac surgery are reoperated because of bleeding. When a surgical cause can be excluded, heparin/protamine mismatch may be considered. Insufficient reversal of heparin and overdosing of protamine may cause postoperative bleeding. The purpose of the study was to evaluate whether a heparin-protamine titration system, Hemochron RxDx, could reduce postoperative bleeding and blood transfusion. Fifty-three patients were included prospectively over a 6-month period. The test group (RxDx group; 28 patients) received heparin and protamine doses calculated using the Hemochron RxDx system, which performs a baseline activated clotting time (ACT) value together with a heparin response test. An accurate heparin dose was calculated based on the Bull dose/response curve. Protamine doses were calculated by the same method. In the control group (25 patients), heparin was administered based on weight (3.5 mg/kg) and monitored by ACT. Heparin was reversed with protamine (1 mg/l mg of total heparin). Postoperative bleeding was significantly lower in the RxDx group (375 mL; range, 125-700 mL) compared with the control group (600 mL; range, 250-1920 mL; p = .018). A reduced number of patients needed blood transfusions in the RxDx group, although this was not statistically significant (19% vs. 38%, respectively; p = .13). Initial heparin dose was significantly reduced in the RxDx group (250 mg; range, 100-375 mg) compared with the control group (300 mg; range, 200-350 mg; p = .04). The additional heparin during cardiopulmonary bypass (CPB) was significantly lower as well 62 (range, 0-185) vs. 100 mg (range, 0-350 mg); p = .04. Initial protamine dose was reduced in the RxDx group 200 (range, 75-340) vs. 350 mg (range, 200-500 mg); p = .0001. Satisfactory end ACT values were obtained in both groups. Using the Hemochron RxDx, we observed a significant reduction in postoperative blood loss, as well as the amount of heparin and initial doses of protamine used during CPB. Individual patient managed anticoagulation during cardiac surgery using dose/response curve techniques based on in vitro analysis of heparin and protamine seems to reduce bleeding.[Abstract] [Full Text] [Related] [New Search]