These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence.
    Author: Kronzon I, Sugeng L, Perk G, Hirsh D, Weinert L, Garcia Fernandez MA, Lang RM.
    Journal: J Am Coll Cardiol; 2009 Apr 28; 53(17):1543-7. PubMed ID: 19389566.
    Abstract:
    OBJECTIVES: This study sought to assess the use of real-time (RT) 3-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) in the evaluation of post-operative mitral valve dehiscence. BACKGROUND: Mitral valve replacement or repair may be complicated by post-operative dehiscence of the valve or annuloplasty ring resulting in clinically significant mitral regurgitation or hemolysis. Diagnosis is generally performed using 2-dimensional transthoracic echocardiography and TEE. Recently, an RT 3D TEE probe has been developed to produce high-quality real-time images. METHODS: We used RT 3D TEE to evaluate mitral regurgitation after mitral valve repair or replacement as a result of mitral ring dehiscence. We studied the additional information and diagnostic utility provided by RT 3D TEE. RESULTS: Eighteen patients were studied (8 patients after repair and 10 after replacement). Real-time 3D TEE allowed accurate evaluation of the pathology, including definition of the type of ring or prosthesis used; description of the site, size, shape, and area of the dehisced segment; and clear definition of the origin of the mitral regurgitation. CONCLUSIONS: In mitral valve dehiscence, RT 3D TEE provides additional information about the exact anatomic characteristics of the dehiscence that can be used to help in planning the most appropriate corrective intervention.
    [Abstract] [Full Text] [Related] [New Search]