These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Retrobulbar optic nerve diameter measured by high-speed magnetic resonance imaging as a biomarker for axonal loss in glaucomatous optic atrophy. Author: Lagrèze WA, Gaggl M, Weigel M, Schulte-Mönting J, Bühler A, Bach M, Munk RD, Bley TA. Journal: Invest Ophthalmol Vis Sci; 2009 Sep; 50(9):4223-8. PubMed ID: 19407026. Abstract: PURPOSE: To assess a novel magnetic resonance imaging (MRI) protocol for quantifying the optic nerve diameter (OND) as a measure of axonal loss in the optic nerve. METHODS: Included in the study was one eye each from 47 subjects, of whom 9 had no eye disease, 16 had preperimetric glaucoma, 11 had a glaucomatous mean visual field defect of <10 dB and 11 of >10 dB. Each subject underwent automated perimetry, scanning laser polarimetry, optic coherence tomography, scanning laser tomography, and ultrafast high-resolution MRI at 3 T. OND was determined 5, 10, and 15 mm behind the eye with a half Fourier-acquired single-shot turbo spin-echo (HASTE)-sequence requiring 1.5 seconds of data acquisition time per slice and providing a spatial resolution of 0.11 mm. A multiple linear regression model was applied to determine correlations (r) among the different techniques. RESULTS: The correlation (r) was <0.37 for OND measurements taken 5 mm behind the eye. At 10 mm behind the eye, r increased to 0.57 and was statistically significant in four out six instances. In the orbital apex 15 mm behind the eye, r reached a maximum of 0.80 and was statistically significant in all instances. OND correlated best with the retinal nerve fiber layer thickness measured by optic coherence tomography. CONCLUSIONS: Retina- or optic nerve head-related surrogate markers for axonal content correlated closely with the OND, although only when it was measured in the orbital apex. High-resolution MRI using an ultrafast HASTE-sequence at 3 T proved useful for OND quantification and may be a valuable asset in future neuroprotection trials.[Abstract] [Full Text] [Related] [New Search]