Search MEDLINE/PubMed
Title: Biosensor based on glutamate dehydrogenase immobilized in chitosan for the determination of ammonium in water samples. Author: Azmi NE, Ahmad M, Abdullah J, Sidek H, Heng LY, Karuppiah N. Journal: Anal Biochem; 2009 May 01; 388(1):28-32. PubMed ID: 19454217. Abstract: An optical biosensor based on glutamate dehydrogenase (GLDH) immobilized in a chitosan film for the determination of ammonium in water samples is described. The biosensor film was deposited on a glass slide via a spin-coating method. The ammonium was measured based on beta-nicotinamide adenine dinucleotide (NADH) oxidation in the presence of alpha-ketoglutaric acid at a wavelength of 340 nm. The biosensor showed optimum activity at pH 8. The optimum chitosan concentrations and enzyme loading were found to be at 2% (w/v) and 0.08 mg, respectively. Optimum concentrations of NADH and alpha-ketoglutaric acid both were obtained at 0.15 mM. A linear response of the biosensor was obtained in the ammonium concentration range of 0.005 to 0.5 mM with a detection limit of 0.005 mM. The reproducibility of the biosensor was good, with an observed relative standard deviation of 5.9% (n=8). The biosensor was found to be stable for at least 1 month when stored dry at 4 degrees C.[Abstract] [Full Text] [Related] [New Search]