These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Assessment of dsigma*/dt (max), a load independent index of contractility, in the canine.
    Author: Black A, Grenz N, Niccole S, Arndt P, Lucht J, Nesvig K, Ewert D, Mulligan L.
    Journal: Cardiovasc Eng; 2009 Jun; 9(2):49-55. PubMed ID: 19466542.
    Abstract:
    The search for a load-independent index of myocardial contractility has been a focus for nearly 100 years. Nearly all of the parameters developed have yielded insight into cardiac function but their clinical utility has been limited. A new index, dsigma*/dt (max), has been proposed to be useful in the clinic. This parameter is expressed as the maximum time rate of change of the pressure normalized circumferential wall stress (sigma* = sigma ( theta )/P, where sigma ( theta ) is circumferential wall stress and P is pressure) for a thick walled sphere model of the left ventricle (LV). This definition for a contractility index renders dsigma*/dt (max) dependent only on LV wall volume (V (m)) and maximum time rate of change of the ventricular volume, dV/dt (max). The index dsigma*/dt (max) has been studied in patients with echocardiogram-derived volume, but up until this point its characteristics in canines have remained unknown. Validating this index in the canine will allow for a more intensive and wide-range investigation of the index that is not available with humans. The purpose of this study was to validate dsigma*/dt (max) as a load-independent measure of contractility in the canine heart with the hope that it was a noninvasive assessment of contractile function. To assess the load independence of dsigma*/dt (max), the index was estimated over a range of preloads (end diastolic volume, EDV) during a vena caval occlusion (VCO). The study was conducted in five canines under various pacing modes [right atrial (RA), right ventricular (RV), left ventricular (LV), and biventricular (BV)] at rates of 90 or 100, and 160 bpm. The animals' ventricular volume measurements were assessed by conductance catheter, calibrated with echocardiography. A 50 Hz filter was applied to the volume signal before differentiation to obtain dV/dt (max). Echocardiography was used to calculate left ventricle mass and V (m). In eight of ten cases, dsigma*/dt (max) was significantly correlated with decreasing EDV (p < 0.05). There was also a significant correlation between dsigma*/dt (max) and dP/dt (max). With a strong correlation between the values of dsigma*/dt (max), dP/dt (max), and EDV in all five subjects, dsigma*/dt (max) is not load independent in the canine heart when preload is altered by a VCO. Further evaluation of this index is required to delineate the situations where dsigma*/dt (max) can be accurately applied.
    [Abstract] [Full Text] [Related] [New Search]