These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cementless acetabular socket revisions using Metasul metal-on-metal bearings. Author: Park KS, Yoon TR, Song EK, Lee KB. Journal: J Arthroplasty; 2010 Jun; 25(4):533-7. PubMed ID: 19493650. Abstract: Thirty-four hips were treated with cementless acetabular socket revisions using a metal-on-metal bearing. The causes of revision were aseptic loosening in 33 hips and septic loosening in 1 hip. Revisions were performed for acetabular sockets in 28 hips and for acetabular sockets and femoral stems in 6 hips. Mean follow-up duration was 6.2 years (range, 4.0-9.1 years), and mean Harris Hip Scores improved from 56 to 92 points. No hip required further revision for aseptic loosening. Focal femoral osteolysis newly developed in zone I in 1 hip, which was treated by curettage and bone grafting. The authors suggest that second-generation metal-on-metal bearings in cementless acetabular socket revisions can achieve good medium-term clinical and radiographic results.[Abstract] [Full Text] [Related] [New Search]