These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Impedance biosensor for peanut protein Ara h 1. Author: Huang Y, Bell MC, Suni II. Journal: Anal Chem; 2008 Dec 01; 80(23):9157-61. PubMed ID: 19551984. Abstract: A reagentless electrochemical impedance biosensor for detection of peanut protein Ara h 1, one of the allergenic proteins found in peanuts, has been demonstrated using an Au substrate onto which an antibody film has been immobilized. Following initial stabilization of the self-assembled monolayer (SAM) through which the antibody is immobilized, the biosensor substrate exhibits stable impedance spectra at different stages of substrate preparation. By fitting the impedance spectra to a Randles equivalent circuit, one can demonstrate that the charge-transfer resistance (R(ct)) increases and the differential capacitance (Cd) decreases with increasing concentration of Ara h 1, although R(ct) exhibits greater sensitivity. The detection limit of this reagentless biosensor is estimated to be less than 0.3 nM. Assuming a Langmuir adsorption isotherm, the dissociation constant of the peanut protein Ara h 1 and its antibody can be calculated as 0.52 nM from the variation in differential capacitance with Ara h 1 concentration.[Abstract] [Full Text] [Related] [New Search]