These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).
    Author: Puskas JD, Halkos ME, Balkhy H, Caskey M, Connolly M, Crouch J, Diegeler A, Gummert J, Harringer W, Subramanian V, Sutter F, Matschke K, EPIC Trial Investigators.
    Journal: J Thorac Cardiovasc Surg; 2009 Jul; 138(1):125-32. PubMed ID: 19577069.
    Abstract:
    OBJECTIVE: During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic clamping. METHODS: Between June 22, 2006, and March 22, 2007, 220 patients requiring coronary artery bypass grafting with at least 2 vein grafts were enrolled. Within each patient, 1 graft was randomly assigned to receive a PAS-Port device, and the other was assigned to receive a hand-sewn anastomosis to the ascending aorta. The primary end point was angiographic patency (<50% stenosis) 9 months after surgical intervention. Secondary end points included average time to complete each anastomosis and 9-month freedom from major adverse cardiac events. RESULTS: One hundred eighty-three patients received matched grafts that were angiographically assessed at 9 months. The 9-month graft patency was 82.0% (150/183) for hand-sewn and 80.3% (147/183) for PAS-Port grafts. The patency rate of PAS-Port anastomoses was statistically noninferior to that of hand-sewn anastomoses (95% lower confidence limit for difference, -7.95%). The freedom from major adverse cardiac events at 9 months was 97.7% for PAS-Port (95% confidence interval, 94.5%-99.0%) and 98.2% for hand-sewn (95% confidence interval, 95.1%-99.3%) grafts. The PAS-port device was associated with a 4.6 +/- 3.9-minute reduction in anastomotic time compared with that seen with a hand-sewn anastomosis (P < .001). CONCLUSIONS: The PAS-Port proximal anastomotic device produces an effective anastomosis with a 9-month patency rate that is comparable with that of a hand-sewn anastomosis. It allows for construction of a proximal anastomosis without aortic clamping and requires less time than a hand-sewn anastomosis.
    [Abstract] [Full Text] [Related] [New Search]