These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Stability of immediately loaded 3- and 6-mm miniscrew implants in beagle dogs--a pilot study.
    Author: Mortensen MG, Buschang PH, Oliver DR, Kyung HM, Behrents RG.
    Journal: Am J Orthod Dentofacial Orthop; 2009 Aug; 136(2):251-9. PubMed ID: 19651356.
    Abstract:
    INTRODUCTION: We compared the stability of 3- and 6-mm long miniscrew implants (MSIs) loaded with orthopedic force levels. METHODS: Using a split-mouth experimental design, we placed MSIs into the jaws of 5 mature beagle dogs and immediately loaded them for 6 weeks. Continuous forces were applied by reciprocally loading pairs of MSIs with nickel-titanium coil springs. The mandibles had the 3-mm MSIs randomly loaded with forces of 600 or 900 g. In the maxilla, the 3- and 6-mm MSIs were randomly assigned and loaded with 600 g of force. An unloaded, control MSI was placed in each quadrant. Overall success was defined as MSIs that remained intact; net success rates excluded MSIs that had sheared off and all implants placed in a dog that frequently chewed his run bars and food bowl. RESULTS: The overall success rates of the loaded and the control 6-mm MSIs were 100%. Overall and net success rates for the 3-mm experimental MSIs were 66.7% and 95.2%, respectively. Similarly, the overall and net success rates of the 3-mm control MSIs were 66.7% and 81.8%, respectively. The overall success rates of the 3-mm mandibular MSIs loaded with 900 and 600 g of force were both 60%; their net success rates were 100% with 900 g and 85.7% with 600 g. Overall success rates of the 3-mm experimental MSIs in the maxilla and the mandible were 80% and 60%, repectively. The net success rates were 100% (maxilla) and 85.7% (mandible). There were no significant (P > 0.05) differences in stability associated with force or location. The loaded 3- and 6-mm MSI pairs demonstrated significant decreases in interimplant distance, averaging 2.2 and 1.8 mm, respectively; the 3-mm MSIs loaded with 900 g showed significantly more displacement than those loaded with 600 g. CONCLUSIONS: Success rates of immediately loaded 3-mm MSIs were significantly lower than those of immediately loaded 6-mm MSIs. Neither force nor location explained differences in the success rates. The linear displacements of the MSIs were associated with load amount rather than implant length.
    [Abstract] [Full Text] [Related] [New Search]