These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. Author: Blankstein R, Shturman LD, Rogers IS, Rocha-Filho JA, Okada DR, Sarwar A, Soni AV, Bezerra H, Ghoshhajra BB, Petranovic M, Loureiro R, Feuchtner G, Gewirtz H, Hoffmann U, Mamuya WS, Brady TJ, Cury RC. Journal: J Am Coll Cardiol; 2009 Sep 15; 54(12):1072-84. PubMed ID: 19744616. Abstract: OBJECTIVES: This study sought to determine the feasibility of performing a comprehensive cardiac computed tomographic (CT) examination incorporating stress and rest myocardial perfusion imaging together with coronary computed tomography angiography (CTA). BACKGROUND: Although cardiac CT can identify coronary stenosis, very little data exist on the ability to detect stress-induced myocardial perfusion defects in humans. METHODS: Thirty-four patients who had a nuclear stress test and invasive angiography were included in the study. Dual-source computed tomography (DSCT) was performed as follows: 1) stress CT: contrast-enhanced scan during adenosine infusion; 2) rest CT: contrast-enhanced scan using prospective triggering; and 3) delayed scan: acquired 7 min after rest CT. Images for CTA, computed tomography perfusion (CTP), and single-photon emission computed tomography (SPECT) were each read by 2 independent blinded readers. RESULTS: The DSCT protocol was successfully completed for 33 of 34 subjects (average age 61.4 +/- 10.7 years; 82% male; body mass index 30.4 +/- 5 kg/m(2)) with an average radiation dose of 12.7 mSv. On a per-vessel basis, CTP alone had a sensitivity of 79% and a specificity of 80% for the detection of stenosis > or =50%, whereas SPECT myocardial perfusion imaging had a sensitivity of 67% and a specificity of 83%. For the detection of vessels with > or =50% stenosis with a corresponding SPECT perfusion abnormality, CTP had a sensitivity of 93% and a specificity of 74%. The CTA during adenosine infusion had a per-vessel sensitivity of 96%, specificity of 73%, and negative predictive value of 98% for the detection of stenosis > or =70%. CONCLUSIONS: Adenosine stress CT can identify stress-induced myocardial perfusion defects with diagnostic accuracy comparable to SPECT, with similar radiation dose and with the advantage of providing information on coronary stenosis.[Abstract] [Full Text] [Related] [New Search]