These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Weight-based, low-dose pediatric whole-body PET/CT protocols. Author: Alessio AM, Kinahan PE, Manchanda V, Ghioni V, Aldape L, Parisi MT. Journal: J Nucl Med; 2009 Oct; 50(10):1570-7. PubMed ID: 19793734. Abstract: UNLABELLED: Adult PET/CT acquisition protocols need to be modified for pediatric imaging to minimize the radiation dose while maintaining diagnostic utility. We developed pediatric PET/CT acquisition protocols customized to patient weight and estimated the dosimetry and cancer risk of these low-dose protocols to communicate basic imaging risks. METHODS: Protocols were developed for whole-body (18)F-FDG imaging of patients in PET mode with a weight-based injected activity (5.3 MBq/kg) and acquisition times (3-5 min/field of view) and for CT for attenuation correction and localization with a weight-based tube current ranging from 10 to 40 mAs. Patients were categorized on the basis of the Broselow-Luten color-coded weight scale. Dosimetry and radiation-induced cancer risk for the PET and CT acquisition in each category were derived from mean patient sizes and the interpolation of factors from accepted patient models. RESULTS: Whole-body pediatric PET/CT protocols require the customization of PET-acquisition settings and task-specific selection of CT technique. The proposed weight-based protocols result in an approximate effective dose ranging from 8.0 mSv for a 9-kg patient up to 13.5 mSv for a 63-kg patient. The radiation dose from the proposed protocols is 20%-50% (depending on patient weight), the dose from PET/CT protocols that use a fixed CT technique of 120 mAs and 120 kVp. The approximate, conservative estimate of additional lifetime attributable risk (LAR) of cancer incidence for females using the proposed protocols was approximately 3 in 1,000, with a variation of 18% across patient categories. For males, the additional LAR of cancer incidence was approximately 2 in 1,000, with a variation of 16% across categories. CONCLUSION: Low-dose PET/CT protocols for 11 patient weight categories were developed. The proposed protocols offer an initial set of acquisition parameters for pediatric PET/CT. The use of multiple categories allows for the continued refinement of dose-reduction parameters to minimize dose while maintaining image quality across the range of pediatric patient sizes.[Abstract] [Full Text] [Related] [New Search]