These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Influence of environmental characteristics and climatic factors on mites in the dust of air-conditioner filters. Author: Wu J, Liu ZG, Ran PX, Wang B. Journal: Indoor Air; 2009 Dec; 19(6):474-81. PubMed ID: 19840146. Abstract: UNLABELLED: To investigate mites in the dust of air-conditioner filters (MACF) in China, a total of 652 dust samples were collected from six cities: Guangzhou (n = 129), Nanchang (n = 127), Shanghai (n = 113), Xian (n = 93), Beijing (n = 93), and Shenyang (n = 79). Tarsonemus granarius was the most dominant species (87.2%). Dermatophagoides pteronyssinus and Dermatophagoides farinae only represented 7.0 and 3.0% of total mites, respectively. With latitude increasing, both mite occurrence rate (P < 0.001) and density (mites/g dust) (P < 0.001) were significantly decreasing. Multivariate regression analysis suggested that the annual average temperature and minimum temperature in different cities had dominant influences on MACF density. The logistic regression analysis revealed that the presence of MACF was positively associated with air-conditioner age, utilization time and power. Wall and window type air-conditioner had higher risk of finding MACF than the floor type air-conditioner. As far as the cleaning interval time of ACF was concerned, higher risk ratio and the highest density of MACF were found in the time stage of >3, < or =12 months. It was also suggested that house type could influence the presence of MACF. A negative association between the house floor and the MACF prevalence was found as well. PRACTICAL IMPLICATIONS: Mites present in the dust of air-conditioner filters are potential indoor threat to asthma and allergy sufferers. In this study, we find that the storage mite Tarsonemus granarius is the predominant species of mites in the dust of air-conditioner filters (MACF). Thus, the possible clinical importance of T. granarius should cause more our attentions in the future. The abundance and distribution of MACF are also found significantly varied in different climatic regions of China. When we try to assess the possible risk of MACF, more attentions should be focused on subtropical region than temperate region. The influence analysis of environmental characteristics on the prevalence of MACF will shed light on the establishment of mite control strategy and the design of mite defense air-conditioner.[Abstract] [Full Text] [Related] [New Search]