These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial.
    Author: Meredith IT, Worthley S, Whitbourn R, Walters DL, McClean D, Horrigan M, Popma JJ, Cutlip DE, DePaoli A, Negoita M, Fitzgerald PJ, RESOLUTE Investigators.
    Journal: JACC Cardiovasc Interv; 2009 Oct; 2(10):977-85. PubMed ID: 19850258.
    Abstract:
    OBJECTIVES: The RESOLUTE trial examined the safety and efficacy of a next-generation zotarolimus-eluting coronary stent, Resolute (Medtronic CardioVascular Inc., Santa Rosa, California). BACKGROUND: Revascularization benefits associated with current drug-eluting stents are often diminished in the presence of complex coronary lesions and in certain patient cohorts. Resolute uses a new proprietary polymer coating that extends the duration of drug delivery to match the longer healing duration often experienced in more complex cases. METHODS: The RESOLUTE trial was a prospective, nonrandomized, multicenter study of the Resolute stent in 139 patients with de novo coronary lesions with reference vessel diameters > or =2.5 and < or =3.5 mm and lesion length > or =14 and < or =27 mm. The primary end point was 9-month in-stent late lumen loss by quantitative coronary angiography. Secondary end points included major adverse cardiac events (MACE) at 30 days, 6, 9, and 12 months; acute device, lesion, and procedure success; and 9-month target vessel failure (TVF), target lesion revascularization (TLR), stent thrombosis, neointimal hyperplastic (NIH) volume, and percent NIH volume obstruction. RESULTS: The 9-month in-stent late lumen loss was 0.22 +/- 0.27 mm. Cumulative MACE were 4.3%, 4.3%, 7.2%, and 8.7% at 30 days, 6, 9, and 12 months, respectively. Acute lesion, procedure, and device success rates were 100.0%, 95.7%, and 99.3%, respectively. At 9 months, TLR was 0.0%, TVF was 6.5%, stent thrombosis was 0.0%, NIH volume was 6.55 +/- 7.83 mm(3), and percent NIH volume obstruction was 3.73 +/- 4.05%. CONCLUSIONS: In this feasibility study, the Resolute stent demonstrated low in-stent late lumen loss, minimal neointimal hyperplastic ingrowth, low TLR, no stent thrombosis, and acceptable TVF and MACE. (The RESOLUTE Clinical Trial; NCT00248079).
    [Abstract] [Full Text] [Related] [New Search]