These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparison of semi-quantitative endotracheal aspirates to quantitative non-bronchoscopic bronchoalveolar lavage in diagnosing ventilator-associated pneumonia.
    Author: Fujitani S, Cohen-Melamed MH, Tuttle RP, Delgado E, Taira Y, Darby JM.
    Journal: Respir Care; 2009 Nov; 54(11):1453-61. PubMed ID: 19863828.
    Abstract:
    BACKGROUND: Current strategies for diagnosing ventilator-associated pneumonia (VAP) favor the use of quantitative methods; however, semi-quantitative cultures of endotracheal aspirates are still commonly used. METHODS: The microbiological results of patients with suspected VAP who had both quantitative cultures with non-bronchoscopic bronchoalveolar lavage (BAL) and semi-quantitative cultures of endotracheal aspirate obtained within 24 hours of each other were retrospectively reviewed and compared, using a quantitative threshold of >or=10(4) colony-forming units/mL as a reference standard. RESULTS: 256 patients with paired cultures were identified. Concordance between endotracheal aspirate (any growth of pathogens) and non-bronchoscopic BAL was complete in 58.2% and completely discordant in 23.8%. The sensitivity and specificity of endotracheal aspirate were 65.4% and 56.1%, which improved to 81.2% and 61.9% when antibiotic management decisions were considered in the analysis. Twenty-six patients had endotracheal aspirate cultures that were falsely negative for pathogens, with 61.5% of these patients demonstrating growth of non-fermenting Gram-negative rods or methicillin-resistant Staphylococcus aureus (MRSA) on non-bronchoscopic BAL. Overall, 45 patients (17.5%) among the entire cohort had false positive endotracheal aspirate cultures, with 19 of these patients (42.2%) demonstrating growth of non-fermenting Gram-negative rods or MRSA. CONCLUSIONS: Semi-quantitative cultures of endotracheal aspirate are poorly concordant with quantitative cultures obtained via non-bronchoscopic BAL. Although the performance of endotracheal aspirate improves when antibiotic treatment is considered, guiding therapy on the basis of semi-quantitative cultures may still result in failure to identify potentially multiple-drug-resistant pathogens, and would also tend to promote excessive antibiotic usage. Our data support the use of quantitative cultures in diagnosing VAP.
    [Abstract] [Full Text] [Related] [New Search]