These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Validation of an electrospray ionization LC-MS/MS method for quantitative analysis of raltegravir, etravirine, and 9 other antiretroviral agents in human plasma samples.
    Author: Quaranta S, Woloch C, Paccou A, Giocanti M, Solas C, Lacarelle B.
    Journal: Ther Drug Monit; 2009 Dec; 31(6):695-702. PubMed ID: 19865000.
    Abstract:
    BACKGROUND: Raltegravir is the first human immunodeficiency virus-1 (HIV-1) integrase inhibitor used in treatment-experienced patients who have evidence of viral replication and HIV-1 strains resistance to multiple antiretroviral regimens. Etravirine is a novel NNRTI, active against HIV-1 strains harboring multiple NNRTI mutations. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of raltegravir, etravirine, and 9 other antiretroviral agents (amprenavir, atazanavir, darunavir, efavirenz, indinavir, lopinavir, ritonavir, saquinavir, and tipranavir) in plasma at the concentrations associated with therapy. MATERIALS AND METHODS: The ritonavir analog, methyl indinavir, and lopinavir-d8 were used as internal standards, added to 100 microL of plasma sample prior to a protein precipitation using methanol. Chromatographic separation was achieved on a C18 HPLC column (Waters Sunfire 100 x 2.1 mm, 3.5 microm) with a mobile phase gradient at a flow rate of 0.3 mL/min. Five microL of sample were injected into the LC-MS/MS system (Waters Quattro Premier XE) to determine concentrations of raltegravir, etravirine, and other antiretroviral agents. RESULTS AND DISCUSSION: This method showed an excellent linearity for all calibration curves (r2 > 0.998). The lower limit of quantification was established at 5 ng/mL for raltegravir and 40 ng/mL for etravirine, with precision and accuracy within +/-20% and 80% to 120% for all analytes. Intraassay and interassay precision and inaccuracy ranged from -9.2% to 6.9% for raltegravir and from -14.3% to 12.3% for etravirine and were less than 15% for all other compounds. No matrix effect was observed for any of the antiretrovirals studied. CONCLUSION: A rapid, specific, and sensitive LC-MS/MS method for quantification of raltegravir, etravirine, and 9 other antiretrovirals in human plasma was developed and was successfully applied for routine therapeutic drug monitoring.
    [Abstract] [Full Text] [Related] [New Search]