  • Title: Symptomatic anaemia 17 years after double valve replacement.
    Author: Wong MH, Chee KH, Azman W.
    Journal: Singapore Med J; 2009 Oct; 50(10):e362-4. PubMed ID: 19907876.
    Abstract:
    A 40-year-old Malay woman presented with increasing lethargy, palpitation and shortness of breath, 17 years after a mitral and aortic valve replacement. A Starr-Edwards prosthetic valve replaced the mitral valve, and a Bjork-Shiley prosthetic valve replaced the aortic valve. Biochemical parameters demonstrated intravascular haemolysis, as evidenced by haemoglobin 7.8 g/dL, reticulocyte count 8.4%, lactate dehydrogenase 2,057 IU/L and low haptoglobulin levels (less than 6 mg/dL). Transoesophageal echocardiography revealed a paravalvular leakage over the mitral valve. The haemoglobin levels remained persistently low despite frequent blood transfusions. She successfully underwent a second mitral valve replacement. Her anaemia resolved subsequently.