These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Simultaneous determination of six flavonoids in Flos Chrysanthemi Indici by RP-HPLC].
    Author: Liu F, Yang Y, Tan X, Bi K, Jia Y.
    Journal: Zhongguo Zhong Yao Za Zhi; 2009 Aug; 34(16):2067-70. PubMed ID: 19938548.
    Abstract:
    OBJECTIVE: To develop an HPLC method for the determination of luteolin-7-O-glycoside, apigenin-7-O-glycoside, linarin, luteolin, apigenin and acacetin in Flos Chrysanthemi Indici simultaneously. METHOD: The reversed phase HPLC system consisting of a C18 column (4.6 mm x 250 mm, 5 microm) and a mixture of acetonitrile and 0.05% phosphate acid with gradient elution as the mobile phase was adopted. The absorbance was monitored at 326 nm. RESULT: The linear response range was 1.08-21.5 mg x L(-1) (r = 0.9990), 0.278-5.57 mg x L(-1) (r = 0.9994), 5.58-112 mg x L(-1) (r = 0.9999), 0.521-10.4 mg x L(-1) (r = 0.9995), 0.162-3.25 mg x L(-1) (r = 0.9999) and 0.288-5.76 mg x L(-1) (r = 0.9998), respectively (n = 6). The average recoveries (n = 9) of six flavonoids were 96.34%-104.0%. All of RSD of precision (n = 6) and repeatability (n = 6) were less than 1.2% and 2.6%. CONCLUSION: The validation data demonstrated that the method was accurate and repeatable, and can be ase to measure the six flavonoids in Flos Chrysanthemi Indici.
    [Abstract] [Full Text] [Related] [New Search]