These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Blood flow volume of uterine arteries in human pregnancies determined using 3D and bi-dimensional imaging, angio-Doppler, and fluid-dynamic modeling. Author: Rigano S, Ferrazzi E, Boito S, Pennati G, Padoan A, Galan H. Journal: Placenta; 2010 Jan; 31(1):37-43. PubMed ID: 19945159. Abstract: The primary aim of this pilot study was to study uterine artery (UtA) blood flow volume in uneventful human pregnancies delivered at term, at mid and late gestation by means of 3D and bi-dimensional ultrasound imaging with angio-Doppler combined with fluid-dynamic modeling. Secondary aims were to correlate flow volume to placental site and to UtA Pulsatility Index (PI). Women with singleton, low-risk pregnancies were examined at mid and late gestation. The structure and course of the uterine artery (UtA) was studied in each patient by means of 3D-angio-Doppler and included vessel diameter D, blood flow velocity and PI (measured along the UtA). Fetal weight estimation and placental insertion site were assessed by ultrasound. A robust fluid-dynamic modeling was applied to calculate absolute flow and flow per unit fetal weight. Mean UtA diameter and blood flow velocity increased significantly (p < 0.0001) from mid-gestation to late gestation from 2.6 mm and 67.5 cm/s, to 3.0 mm and 85.3 cm/s, respectively, yielding an increasing absolute flow troughout gestation. h coefficient, derived by fluid-dynamic modeling to calculate mean velocity, increased significantly from 0.52 at mid-gestation to 0.57 at late gestation. UtA blood flow volume ml/min/kg-fetal weight was significantly higher at mid-gestation than at late gestation (535 ml/min/kg vs 193 ml/min/kg; p < 0.0001). In cases with strictly lateral placentas the ipsilateral UtA accommodates at mid and late gestation 63% and 67% of the total UtA flow. In central placentas UtA flow was evenly distributed between the two vessels. An inverse correlation was observed between PI and blood flow volume ml/min/kg (Pearson's coefficient r = -0.54). Our work confirms the technological and methodological limitations in the measurement of uterine artery blood flow. However, Doppler measurements supported by three-dimensional angio imaging of the uterine vessel, high resolution imaging and diameter measurement, and a robust mathematical model of local circulation adds a genuine new area of investigation into human uterine circulation during pregnancy.[Abstract] [Full Text] [Related] [New Search]