These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Decision criteria for pure-tone detection used by two age groups of normal-hearing and hearing-impaired listeners. Author: Marshall L. Journal: J Gerontol; 1991 Mar; 46(2):P67-70. PubMed ID: 1997578. Abstract: Response criteria from a yes-no task and detection thresholds from two test procedures were measured for four groups of adults: younger normal-hearing, older normal-hearing, younger hearing-impaired, and older hearing-impaired. The two test procedures were an audiological procedure (which does not control for response bias) and a 21FC adaptive procedure (which does control for bias). The signal was a 500 or 4000 Hz tone presented in quiet. All four groups showed an equally conservative response bias in the yes-no task. In addition, neither age nor hearing loss affected the difference (6.5 dB) between the two threshold measures.[Abstract] [Full Text] [Related] [New Search]