These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A Comparison of fixed-hole and slotted-hole dynamic plates for anterior cervical discectomy and fusion.
    Author: Hong SW, Lee SH, Khoo LT, Yoon SH, Holly LT, Shamie AN, Wang JC.
    Journal: J Spinal Disord Tech; 2010 Feb; 23(1):22-6. PubMed ID: 20051923.
    Abstract:
    STUDY DESIGN: A retrospective review of clinical data at 1 institution was performed. OBJECTIVES: To compare the clinical and radiologic outcomes between fixed-hole and slotted-hole dynamic cervical plates. SUMMARY OF BACKGROUND DATA: Anterior cervical plating is commonly used to increase stability and promote spinal fusion. Two techniques, fixed-hole dynamic plating that uses variable angled screws and slotted-hole dynamic plating that permits sliding, are viable options, but there have been no clinical studies comparing their effectiveness. METHODS: Fifty-six patients at 1 institution having anterior cervical discectomy and fusion for degenerative disease over a 5-year period were entered into this study. Surgeries were performed with 1 of the dynamic plates for 1 to 3 levels. For the slotted-hole dynamic plate group, a slotted-hole plate was used (ABC, Aesculap, Tuttlingen, Germany or C-tek, Biomet, Parssipany, NJ) and for the fixed-hole dynamic plated group, a variable angled screw was used (C-tek, Biomet, Parssipany, NJ). Radiographic measurements included were graft subsidence, lordotic angle change from each end plate of fusion construct, and implant translation from end plates after a minimum of 12 months follow-up. Fusion state and clinical outcome using Odom's criteria were also evaluated. RESULTS: Demographics were not different among patient populations. The average age of the patients was 51.0 years (range: 27 to 77 y). Mean follow-up period was 20.6 months (range: 12 to 41 mo). Slotted-hole dynamic plates were used for 29 patients (ABC plate, 17; C-tek plate, 12) and fixed-hole dynamic plates for 27 patients. Clinical outcomes and pseudoarthrosis rates were similar for both types of plates. Radiographic measurements showed a statistically significant increased incidence of graft subsidence and implant translation with the slotted-hole dynamic plates. Loss of lordosis was also greater in the slotted-hole dynamic plated group, although the difference was not statistically significant. CONCLUSIONS: The use of a fixed-hole dynamic plate is more favorable in regards to graft subsidence and implant translation in the follow-up period, although clinical outcome and fusion rates are similar in patients with either the fixed-hole or slotted-hole dynamic plates.
    [Abstract] [Full Text] [Related] [New Search]