These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Echocardiography in the potential heart donor. Author: Venkateswaran RV, Townend JN, Wilson IC, Mascaro JG, Bonser RS, Steeds RP. Journal: Transplantation; 2010 Apr 15; 89(7):894-901. PubMed ID: 20075789. Abstract: BACKGROUND: The relationship between echocardiographic left ventricular(LV) systolic function (E-function) and pulmonary artery catheter(PAC) assessment of hemodynamic function (H-function) in potential heart donors is ill defined. We investigated this and determined (a) whether optimization could improve abnormal E-function, (b) feasibility and usefulness of repeat transthoracic echocardiography (TTE), and (c) whether thyroid status and therapy affected E-function. MATERIALS AND METHODS: Transthoracic E-function imaging was performed at baseline and 4 hr in potential donors (enrolled in a randomized controlled trial of tri-iodothyronine+/-methylprednisolone [MP] therapy) undergoing PAC-guided algorithmic optimization. Images were analyzed post hoc for LV wall thickness, ejection fraction, and Tei index. RESULTS: The study comprised 66 donors. Both LV ejection fraction (LVEF) and LV-Tei correlated with cardiac index (CI; P<0.001), and LV Tei was most frequently measurable and repeatable(P=0.01). Normal LVEF independently predicted end-assessment H-functional suitability (odds ratio 1.05, 95% confidence interval 1.007-1.088 [P=0.021]) but had poor specificity. Initial subnormal E-function was identified in 29 of 66 of hearts, of which 58% (17/29) achieved H-function suitability criteria. In 52 hearts, repeat E-function assessment was possible. Nineteen of 52 had initially subnormal E-function, which improved in over half (53%). H-function could be manipulated to meet functional suitability criteria for transplant even without E-function change. Neither initial thyroid status nor hormonal therapy affected LV function. CONCLUSIONS: Echocardiography is possible in most potential heart donors. Normal E-function predicts hemodynamic suitability for transplantation but lacks specificity. More than 50% of hearts with subnormal E-function can attain hemodynamic transplantation criteria after donor management. Repeat echocardiography is feasible but has a limited role. Both initial echocardiography and PAC-guided management should be used routinely.[Abstract] [Full Text] [Related] [New Search]