These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Doppler echocardiographic evaluation of streptokinase lysis of thrombosed right-sided St. Jude Medical valves in patients with congenital heart defects.
    Author: Fyfe DA, Taylor AB, Kline CH, Sade RM, Gillette PC.
    Journal: Am Heart J; 1991 Apr; 121(4 Pt 1):1156-60. PubMed ID: 2008839.
    Abstract:
    Four episodes of St. Jude Medical prosthesis leaflet thrombosis were serially evaluated by two-dimensional and Doppler echocardiography during treatment with streptokinase. Three patients aged 4, 11, and 24 years with congenital heart disease had St. Jude Medical valves in pulmonary positions (two cases) for tetralogy of Fallot and in the tricuspid position (one case). The duration of thrombosis was not known in any patient. Leaflet immobility and its resolution were demonstrated by echocardiography and were confirmed fluoroscopically. Continuous wave Doppler echocardiography showed abnormal stenotic gradients in thrombosed valves that were reduced after thrombolysis. These studies demonstrate the utility of two-dimensional and Doppler echocardiography in serial evaluation of prosthetic pulmonary and tricuspid valve thrombosis during thrombolysis.
    [Abstract] [Full Text] [Related] [New Search]