These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Purse-string capsule repair to reduce proximal femoral arthroplasty dislocation for tumor--a novel technique with results. Author: Henderson ER, Jennings JM, Marulanda GA, Palumbo BT, Cheong D, Letson GD. Journal: J Arthroplasty; 2010 Jun; 25(4):654-7. PubMed ID: 20097040. Abstract: Hip joint dislocation is the most common complication after proximal femoral arthroplasty with a large endoprosthesis. Average dislocation rates are around 15%. In an attempt to decrease dislocations after proximal femoral arthroplasty for tumor resections, we devised a novel closure of the hip capsule. This technique uses a 3-mm cottony Dacron suture placed about the hip capsule in a circumferential, purse-string manner. Thirty-nine patients received hip hemiarthroplasty with purse-string capsular closure. Seven patients were lost to follow-up, leaving 36 patients available for analysis. One patient dislocated (2.8%). We believe this technique is useful in preventing dislocation in patients undergoing proximal femoral arthroplasty for oncologic disease.[Abstract] [Full Text] [Related] [New Search]