These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Attenuation correction of somatostatin receptor SPECT by integrated low-dose CT: is there an impact on sensitivity?
    Author: Steffen IG, Mehl S, Heuck F, Elgeti F, Furth C, Amthauer H, Ruf J.
    Journal: Clin Nucl Med; 2009 Dec; 34(12):869-73. PubMed ID: 20139819.
    Abstract:
    AIM: Somatostatin receptor scintigraphy (SRS) is an established imaging modality for neuroendocrine tumors (NET). Additional single photon emission computed tomography (SPECT-CT) not only permits image fusion but also attenuation correction (AC) of SPECT data. This study evaluated whether attenuation corrected SPECT-images (SPECT[AC]) are more sensitive than nonattenuation corrected SPECT-reconstructions (SPECT[NAC]) for the detection of NET lesions. METHODS: The imaging data (planar In-111-octreotide scintigraphy and SPECT-CT) of 50 consecutive patients (28 male; 22 female; age, 34-80; mean, 65 years) with NET were included in this retrospective analysis. SPECT data were reconstructed with and without integrated CT-based AC and then analyzed by 2 experienced readers for the presence of pathologic uptake in a blinded consensus reading. Fused SPECT-CT, contemporary CT/MRI, and clinical as well as imaging follow-up served as a reference standard. All foci were rated in both the SPECT(NAC)- and SPECT(AC)-reconstructions for intensity and contrast using a 6-point-score ("0 = no uptake/no delineation from surrounding tissue" to "5 = very high uptake/very strong delineation from surrounding tissue"). The scores were analyzed in a 6 x 6 contingency table using the McNemar Bowker test. RESULTS: A total of 222 pathologic foci were detected by SPECT(NAC) and 227 foci by SPECT(AC), respectively. In 67 of 227 foci (29.5%), focus intensity/contrast increased after AC, whereas only 5 foci showed a decrease (P < 0.001). Sensitivity increased by 2.2% (P = 0.025; 95% CI: 0.02%-4.1%) as 5 foci were detected only by SPECT(AC). However, as these 3 patients were already diagnosed with systemic disease, there was no influence on the therapeutic strategy chosen. CONCLUSION: Attenuation correction of somatostatin receptor scintigraphy-SPECT significantly improves focus visualization and, albeit slightly, also significantly increases sensitivity.
    [Abstract] [Full Text] [Related] [New Search]