These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Surface structural conformations of fibrinogen polypeptides for improved biocompatibility.
    Author: Yaseen M, Zhao X, Freund A, Seifalian AM, Lu JR.
    Journal: Biomaterials; 2010 May; 31(14):3781-92. PubMed ID: 20153048.
    Abstract:
    This work reports on how incorporation of silica nanocages into poly(urethane) copolymers (PU) affects conformational orientations of adsorbed fibrinogen and how different surfaces subsequently influenced HeLa cell attachment and proliferation. Incorporation of 2 wt% silica nanocages into poly(urethane) (PU4) substantially altered the surface topography of the films and some 50% of the surface was covered with the nanocages due to their preferential exposure. AFM studies revealed the deposition of a dense protein network on the soft polymeric domains of PU4 and much reduced fibrinogen adsorption on the hard nanocage domains. As on the bare SiO(2) control surface, fibrinogen molecules adsorbed on top of the hard nanocages mainly took the dominant trinodular structures in monomeric and dimeric forms. In addition, net positively charged long alpha chains were prone to being hidden beneath the D domains whilst gamma chains predominantly remained exposed. Dynamic interfacial adsorption as probed by spectroscopic ellipsometry revealed fast changes in interfacial conformation induced by electrostatic interactions between different segments of fibrinogen and the surface, consistent with the AFM imaging. On the PU surfaces without nanocage incorporation (PUA), however, adsorbed fibrinogen molecules formed beads-like chain networks, consistent with the structure featured on the soft PU4 domains, showing very different effects of surface chemical nature. Monoclonal antibodies specific to the alpha and gamma chains showed reduced alpha but increased gamma chain binding at the silicon oxide control and PU4 surfaces, whilst on the PUA, C18 and amine surfaces (organic surface controls) the opposite binding trend was detected with alpha chain binding dominant, showing different fibrinogen conformations. Cell attachment studies revealed differences in cell attachment and proliferation, consistent with the different polypeptide conformations on the two types of surfaces, showing a strong preference to the extent of exposure of gamma chains.
    [Abstract] [Full Text] [Related] [New Search]