These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Application of the Willis covered stent in the treatment of aneurysm in the cisternal segment of the internal carotid artery: a pilot comparative study with midterm follow-up. Author: Zhu YQ, Li MH, Fang C, Tan HQ, Wang W, Zhang PL, Cheng YS, Wang JB, Ma LT. Journal: J Endovasc Ther; 2010 Feb; 17(1):55-65. PubMed ID: 20199268. Abstract: PURPOSE: To compare the use of the Willis stent-graft versus coil embolization for complicated aneurysms in the cisternal segment of the internal carotid artery (ICA). METHODS: Thirty-four patients (19 women; mean age 46.7+/-16.8 years, range 3-79) with 36 complicated aneurysms were treated either by Willis covered stents (n = 19) or by coil embolization (n = 17). Follow-up angiography was performed to investigate aneurysm recurrence, endoleak, and parent artery stenosis. Kaplan-Meier curves were constructed to compare the freedom from recurrence and parent artery stenosis rates in both groups. Clinical follow-up data were retrospectively analyzed and categorized as fully recovered, improved, unchanged, or worsened. RESULTS: In the covered stent group, total exclusion was immediately achieved in 13 aneurysms; there were 5 minor endoleaks and 1 delivery failure. In the patients treated with coil embolization, total/near-total occlusion was achieved in 7 aneurysms, subtotal in 8, and partial in 2. Acute thrombosis occurred in 1 patient in each group, while 1 patient experienced recurrent hemorrhage after embolotherapy. Follow-up angiography (mean 14.3+/-9.4, range 3-31) revealed that 16 aneurysms were completely isolated in the stent-graft group, with only 2 mild in-stent stenoses. Eighteen months after the procedure, Kaplan-Meier analysis showed recurrence-free rates of 93.3% and 50% for the stent-graft versus coil groups, respectively; freedom from parent artery stenosis was 87.5% and 100%. Symptoms were fully eliminated in 9 patients in each group; they were improved in 3 and 5, unchanged in 2 and 2, and worsened in 1 and 0, respectively, at the end of the follow-up period. CONCLUSION: Willis stent-graft application is an alternative to treat complicated aneurysms in the cisternal segment of the ICA. In the case of a tortuous parent artery or potential side branch coverage, however, it is still not a first choice therapy.[Abstract] [Full Text] [Related] [New Search]