These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Penetration of screw into the wall of thoracic aorta after stabilization of thoracic spine--case report.
    Author: Zietek P, Bohatyrewicz A, Jakuszewski M, Karaczun M, Kotrych D, Kacperski M, Dobiecki K.
    Journal: Chir Narzadow Ruchu Ortop Pol; 2009; 74(6):377-8. PubMed ID: 20201338.
    Abstract:
    In our research we have discussed a rare case of penetration of screw into the thoracic aorta after stabilization of thoracic spine due to compressive fracture of IV thoracic vertebra. We have focused on existence of potential danger of damage of aorta during stabilization of the posterior part of thoracic spine. We have emphasized the meaning of prophylactic implantation of stent-graft into the site of potential damage of aorta before the restabilization of the vertebral column.
    [Abstract] [Full Text] [Related] [New Search]