These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Atomic force microscopy study of immunosensor surface to scale down the size of ELISA-type sensors.
    Author: Volkov D, Strack G, Halámek J, Katz E, Sokolov I.
    Journal: Nanotechnology; 2010 Apr 09; 21(14):145503. PubMed ID: 20234083.
    Abstract:
    Here we describe the use of atomic force microscopy (AFM) to study the nanoscale mechanics of the molecular layers of a popular immunosensor, ELISA (enzyme-linked immunosorbent assay) type. We characterize the sensor surface in terms of brush length and grafting density of the molecular layers. The obtained data demonstrated that a reliable reading of the immunosignal (a suggested dimensionless combination of brush length and grafting density) can be attained from an area as small as approximately 3 microm(2). This is approximately 4 million times smaller compared to typical ELISA sensors. The immunosensor described is composed of a molecular mix of two different antigens. Intriguingly, we find that AFM can reliably distinguish between having the immunosignal from either antibody and from both antibodies together. This was impossible to get by using standard optical detection methods.
    [Abstract] [Full Text] [Related] [New Search]