  • Title: Synthesis and application of a T-2 toxin imprinted polymer.
    Author: De Smet D, Monbaliu S, Dubruel P, Van Peteghem C, Schacht E, De Saeger S.
    Journal: J Chromatogr A; 2010 Apr 23; 1217(17):2879-86. PubMed ID: 20299027.
    Abstract:
    The synthesis of a T-2 toxin imprinted polymer and its application in food analysis are reported for the first time. A molecularly imprinted polymer (MIP) for the selective recognition of T-2 toxin (T-2) was synthesized by bulk polymerization. Methacrylamide and ethyleneglycol dimethacrylate were applied as functional monomer and cross-linker, respectively. Molecularly imprinted solid-phase extraction (MISPE) procedures were optimized for further application in the analysis of T-2. Scatchard plot analysis revealed that two classes of imprinted binding sites were formed in the imprinted polymer. The dissociation constant (KD) of the higher affinity binding sites was 7.0 micromol/l, while the KD of the lower affinity binding sites was 54.7 micromol/l. The performance of the MIP throughout the clean-up of spiked maize, barley and oat sample extracts was compared with the results obtained when using non-imprinted polymer, OASIS HLB and immunoaffinity columns (IAC). Depending on the food matrix and the spiked concentration, recoveries after MISPE and non-imprinted solid-phase extraction varied respectively from 60% to 73% and from 21% to 57%. Recoveries obtained after clean-up using OASIS HLB and IAC were in the range of 74-104% and 60-85%, respectively. Although highest recoveries were obtained with OASIS HLB sorbents, the designed MIP and the IAC were superior regarding selectivity, cross-reactivity, matrix effect, limits of detection (LOD) and limits of quantification (LOQ). Depending on the matrix, LOD after MISPE ranged from 0.4 microg/kg to 0.6 microg/kg and LOQ from 1.4 microg/kg to 1.9 microg/kg. LOD and LOQ after OASIS HLB clean-up varied from 0.9 microg/kg to 3.5 microg/kg and from 3.1 microg/kg to 11.7 microg/kg, respectively. The LOD and LOQ values obtained with IAC were in the range of 0.3-2.3 microg/kg and 1.0-7.7 microg/kg, respectively. Analysis of 39 naturally contaminated samples (maize, barley and oat) by liquid chromatography tandem mass spectrometry revealed that the MIP could be an excellent alternative for clean-up of contaminated food samples.
    [Abstract] [Full Text] [Related] [New Search]